Descripción
Technical characteristics
• 1 or 2 plane On-site Balancer
• 10 sets balancing data storage
• Process clarified by vector graph
• Trial weight estimation
• Trial can remain or be removed
• Trial validity test
• Rotating speed measurement range(with laser-aimed tacho sensor):180-24000 r/min
• Rotating speed range for balancing:60-8000 r/min
• Balancing weight can be broken up to 2 required position
• Rechargeable battery for more than 10 hours continuous operation
• Dual-channel vibration Analyzer
• 400 lines FFT spectrum
• Acceleration envelope demodulation
• Storage: 240 vibration values & 62 waveforms of 1024 samples